A frost wall foundation is a short poured concrete wall that runs from a footing set below the frost line up to just above finished grade, with a slab poured inside it. In Ohio it is the standard way to put a garage, a slab home, a sunroom or a room addition on solid ground without digging a full basement. You will also hear it called a stem wall, a frost footing or a T foundation, depending on who is talking.
How a frost wall is put together
The footing goes in first, at the depth your building department sets. That is 38 inches in Summit County, 32 in Columbus and Montgomery County, and 36 or 42 inches in Cleveland depending on which city figure applies. The wall is formed and poured on top of the footing and brought up above the finished grade, typically at least 6 inches, or 4 inches where brick or stone veneer will sit on it, so framing and siding stay out of the dirt and splash water.
Inside the wall, the ground is filled and compacted, a layer of stone goes down, and the floor slab is poured last. The slab rests on that fill. The perimeter of the building, the part carrying the walls and roof, rests on the frost wall and its footing. When the ground freezes in January, the load bearing perimeter is sitting below the frozen layer and stays where it was poured.
Frost wall or monolithic slab
The other common choice for a garage or slab home is a monolithic slab, where the floor and a thickened edge are poured in one shot at grade. It is quicker and cheaper, and on the right project it is the right call. The catch in Ohio is frost. A thickened edge poured at grade sits in soil that freezes, so on its own it does not meet the frost protection requirement.
The Residential Code of Ohio lets a small detached accessory building skip frost protection: light frame construction, 600 square feet or less, with an eave height of 10 feet or less. A typical one car detached garage can fit. A two car garage usually runs past 600 square feet, and an attached garage or any part of the house never qualifies. Those need a frost wall, a monolithic slab built as a frost protected shallow foundation with rigid insulation, or another approved method. Our post on monolithic slab foundations in Ohio covers when that route makes sense.
Where frost walls get used
Attached garages. The garage wall shares a line with the house, and any movement shows up as cracked drywall at the connecting door and a gap at the roofline. The garage frost wall goes down to the same depth as the house footing it ties into.
Room additions and sunrooms. An addition on a slab next to a house with a basement needs a frost wall around its outside edge. Where the addition meets the existing basement wall, the new footing has to bear on undisturbed soil, which often means stepping down through the old backfill. Our guide to home addition foundations in Ohio goes into that connection.
Slab on grade homes. A single story home built on a slab sits on a frost wall perimeter with the slab inside, the same way a garage does, just with more interior footings for bearing walls.
Detached garages over the exemption size. Once a detached garage passes 600 square feet, it needs the same frost protection as any other structure.

Poured or block
Frost walls can be laid in concrete block or poured. A poured wall is usually formed and poured in a day once the footing has set, comes out of the forms dead flat and plumb for the sill plate, and has no mortar joints for water to work through. Block works, but on a garage or addition where the slab edge and sill sit right at grade, a monolithic poured wall gives fewer places for water and frost to get a grip. We form frost walls the same way we form full basement walls, with robotic total station layout, so the top of wall lands at the elevation the plans call for.
Details that keep the slab from cracking at the wall
The slab inside a frost wall should be separated from the wall with an isolation joint so the two can move independently. The fill under the slab needs to be placed in lifts and compacted, because a slab poured over loose fill inside a frost wall will settle in the middle and crack along a line a few feet in from the wall. For heated spaces, rigid insulation along the inside face of the frost wall and under the slab edge keeps the floor warmer and is usually required by the energy code. Anchor bolts or straps are set in the top of the wall while the concrete is wet, at the spacing on the plans.
Frequently asked
How tall is a frost wall?
Tall enough to reach from a footing at frost depth to the required height above finished grade. With a 32 inch frost depth in Columbus and an 8 inch footing, that works out to about 30 inches of wall on a flat lot, and more in Summit County or Cleveland. On a sloped lot one side can be much taller, and the footing steps to follow the grade.
Can I add a frost wall under an existing garage slab?
Not practically. The fix for a heaving garage slab without frost protection is usually underpinning the perimeter or replacing it. Getting the frost wall in at the start costs far less.
Armada pours frost walls, footings and full foundations across northeast Ohio (440) 526-1980, central Ohio (614) 344-5104 and southwest Ohio (513) 409-0053. Request a quote with your plans and lot address.